MOBY::Client::Exception::MobyExceptionCodes
Library that contains structure of exception codes and exception descriptions
Jose Manuel Rodriguez Carrasco -jmrodriguez@cnio.es- (INB-CNIO)
Function: An exception code is received given as input. The method retrieves the exception description. For more information, see below tables and BioMoby exception protocol.
Args: Number of exception code.
Returns: Description of exception given as input.
Code | Name | Description |
200 | UNKNOWN_NAME | Setting input data under a non-existing name, or asking for a result using an unknown name |
201 | INPUTS_INVALID | Input data are invalid; they do not match with their definitions, or with their dependency conditions |
202 | INPUT_NOT_ACCEPTED | Input data are not accepted |
221 | INPUT_REQUIRED_PARAMETER | Service require parameter X |
222 | INPUT_INCORRECT_PARAMETER | Incorrect parameter X |
223 | INPUT_INCORRECT_SIMPLE | Incorrect input in simple article |
224 | INPUT_INCORRECT_SIMPLENB | Service requires two or more simple articles |
225 | INPUT_INCORRECT_COLLECTION | Incorrect input in collection article |
226 | INPUT_EMPTY_OBJECT | Empty input object |
231 | INPUT_EMPTY_MOBYCONTENT | Empty MOBYContent |
232 | INPUT_INCORRECT_MOBYDATA | QueryID does not exists |
233 | INPUT_EMPTY_MOBYDATA | Empty MOBYData |
233 | INPUT_EMPTY_MOBYDATA | Empty MOBYData |
Code | Name | Description |
300 | NOT_RUNNABLE | The same job has already been executed, or the data that had been set previously do not exist or are not accessible anymore |
301 | NOT_RUNNING | The job has not yet been started |
302 | NOT_TERMINATED | The job is not interruptible for some reason |
Code | Name | Description |
400 | NO_METADATA_AVAILABLE | There are no metadata available |
Code | Name | Description |
500 | PROTOCOLS_UNACCEPTED | Server does not agree on using any of the proposed notification protocols |
Code | Name | Description |
600 | INTERNAL_PROCESSING_ERROR | A generic error during internal processing |
601 | COMMUNICATION_FAILURE | A generic network failure |
602 | UNKNOWN_STATE | Unknown State |
603 | NOT_IMPLEMENTED | Not implemented method in question |
621 | SERIVCE_NOT_AVAILABLE | Service not available |
Code | Name | Description |
700 | OK | Everything was ok |
701 | SERVICE_INTERNAL_ERROR | Specific errors from the BioMOBY service |
702 | OBJECT_NOT_FOUND | Object not found with the given input |
703 | DATA_NOT_LONGER_VALID | A sequence indentifier that has been retracted |
704 | INPUT_BIOLOGICALLY_INVALID | The input does not make sense biologically |
705 | DATA_TRANSFORMED | The input data is transformed |
721 | INCORRECT_ARTICLE_NAME | The specified name of MOBYData article is wrong or does not exist |
722 | INCORRECT_OBJECT_TYPE | Incorrect Object type from specified MOBYData article |
723 | INCORRECT_ARTICLENAME_OBJECT | The specified article name of BioMOBY Object is wrong or does not exist |
724 | INCORRECT_NAMESPACE_OBJECT | The namespace of specified BioMOBY Object is invalid |
731 | INCORRECT_ARTICLENAME_SECONDARY | The specified name of secondary is wrong or does not exist |
732 | INCORRECT_DATA_TYPE_SECONDARY | Incorrect data type from specified secondary article |
733 | INCORRECT_VALUE_SECONDARY | The value of secondary article is invalid. It is not inside of correct range |
734 | INCORRECT_VALUE_AND_DEFAULTVALUE_SECONDARY | There is not SECONDARY value and registered SECONDARY article has not default value |